{"id":16205,"date":"2026-01-12T11:32:57","date_gmt":"2026-01-12T10:32:57","guid":{"rendered":"https:\/\/themacs-engineering.com\/?p=16205"},"modified":"2026-01-12T12:49:01","modified_gmt":"2026-01-12T11:49:01","slug":"un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2","status":"publish","type":"post","link":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/","title":{"rendered":"20 K cryogenic bench for characterising liquid hydrogen materials"},"content":{"rendered":"<h1 class=\"ai-optimize-6 ai-optimize-introduction\">Thermo-physical characterisation of materials down to 20 K for liquid hydrogen<\/h1>\r\n<h2 class=\"ai-optimize-7 ai-optimize-introduction\"><a href=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/THEMACS-INGENIERIE-Banc-de-mesure.pdf\">Download the brochure<\/a><\/h2>\r\n<p class=\"ai-optimize-6 ai-optimize-introduction\"><b>THEMACS Engineering<\/b> markets a <b>thermophysical property measurement bench<\/b> dedicated to <b>liquid hydrogen<\/b> applications, operational down to <b>20 K<\/b>.<\/p>\r\n<p class=\"ai-optimize-7\">This system enables the precise characterization of materials and components under cryogenic conditions (thermal conductivity, thermal resistance, associated behaviors), as close as possible to real-world conditions.<\/p>\r\n<p class=\"ai-optimize-8\">Designed for R&amp;D and industry, this bench is intended for players in the <b>storage, transport, and hydrogen technologies<\/b> sectors who require reliability, traceability, and compliance with measurement standards.<\/p>\r\n<p class=\"ai-optimize-6 ai-optimize-introduction\"><a href=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1634\" height=\"1909\" class=\"alignnone size-full wp-image-16556 img-responsive\" src=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg\" alt=\"Banc de mesure cryog\u00e9nique 20K\" srcset=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg 1634w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc-257x300.jpg 257w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc-876x1024.jpg 876w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc-768x897.jpg 768w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc-1315x1536.jpg 1315w\" sizes=\"(max-width: 1634px) 100vw, 1634px\" \/><\/a><\/p>\r\n\r\n<h2 class=\"ai-optimize-9\"><strong>Features:<\/strong><\/h2>\r\n<p class=\"ai-optimize-10\">Temperature range: 6 to 300K<\/p>\r\n<p class=\"ai-optimize-11\">&#8211; Air-cooled compressor (no additional water circuit required)<\/p>\r\n<p class=\"ai-optimize-12\">&#8211; Power supply: 220V single-phase<\/p>\r\n<p class=\"ai-optimize-13\">&#8211; Vacuum chamber with 600mm internal diameter<\/p>\r\n<p class=\"ai-optimize-14\">&#8211; Temperature control via PID regulator<\/p>\r\n<p class=\"ai-optimize-15\">&#8211; Pumping system: Scroolvac primary pump and 450L\/s turbo-molecular pump<\/p>\r\n<p class=\"ai-optimize-16\">&#8211; Vacuum chamber up to 10E-7mbar<\/p>\r\n<p class=\"ai-optimize-17\">&#8211; Parameter control unit adaptable to your needs<\/p>\r\n\r\n<h2 class=\"ai-optimize-18\"><strong>Option:<\/strong><\/h2>\r\n<h3 class=\"ai-optimize-19\"><strong>Thermal properties:<\/strong><\/h3>\r\n<p class=\"ai-optimize-20\">Measurement of thermal conductivity and thermal capacity using a modulated method. Suitable for anisotropic materials (composite and multilayer materials). Possibility of installing 4 samples in the chamber<\/p>\r\n<p class=\"ai-optimize-7\"><a href=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/enceinte1-scaled.jpg\"><img decoding=\"async\" width=\"2560\" height=\"1710\" class=\"alignnone size-full wp-image-16557 img-responsive\" src=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/enceinte1-scaled.jpg\" alt=\"\" srcset=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/enceinte1-scaled.jpg 2560w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/enceinte1-300x200.jpg 300w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/enceinte1-1024x684.jpg 1024w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/enceinte1-768x513.jpg 768w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/enceinte1-1536x1026.jpg 1536w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/enceinte1-2048x1368.jpg 2048w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/a><\/p>\r\n\r\n<h3 class=\"ai-optimize-21\"><strong>6K Guarded Hot Plate:<\/strong><\/h3>\r\n<p class=\"ai-optimize-22\">Used to measure foam or multi-layer insulation using the hot plate method at temperatures between 10 and 300K. Sample size is 300x300mm.<\/p>\r\n<p class=\"ai-optimize-10\"><a href=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/pcg-scaled.jpg\"><img decoding=\"async\" width=\"2560\" height=\"1331\" class=\"alignnone size-full wp-image-16561 img-responsive\" src=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/pcg-scaled.jpg\" alt=\"Plaque chaude gard\u00e9e \u00e0 20Kelvin\" srcset=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/pcg-scaled.jpg 2560w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/pcg-300x156.jpg 300w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/pcg-1024x532.jpg 1024w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/pcg-768x399.jpg 768w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/pcg-1536x799.jpg 1536w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/pcg-2048x1065.jpg 2048w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/a><\/p>\r\n\r\n<h3 class=\"ai-optimize-23\"><strong>Leak test:<\/strong><\/h3>\r\n<p class=\"ai-optimize-24\">Leak tests on circuit components performed from 10 to 300K under hydrogen or helium pressure up to 200bar<\/p>\r\n<p class=\"ai-optimize-25\">Up to 3 pieces of equipment can be tested in the measurement area<\/p>\r\n<p class=\"ai-optimize-26\">Measurement area 200 m in diameter and 250 mm high<\/p>\r\n<p class=\"ai-optimize-27\">Leak detection threshold: 10-13 Pa.m3\/s<\/p>\r\n<p class=\"ai-optimize-8\"><a href=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/fuite2.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"2123\" height=\"985\" class=\"alignnone size-full wp-image-16559 img-responsive\" src=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/fuite2.jpg\" alt=\"\" srcset=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/fuite2.jpg 2123w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/fuite2-300x139.jpg 300w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/fuite2-1024x475.jpg 1024w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/fuite2-768x356.jpg 768w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/fuite2-1536x713.jpg 1536w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/fuite2-2048x950.jpg 2048w\" sizes=\"(max-width: 2123px) 100vw, 2123px\" \/><\/a><\/p>\r\n\r\n<h3 class=\"ai-optimize-28\"><strong>Tensile tests:<\/strong><\/h3>\r\n<p class=\"ai-optimize-29\">30kN tensile testing machine for tensile tests. Thermal bridge breaker for rapid temperature reduction of the sample.<\/p>\r\n\r\n<h3 class=\"ai-optimize-27\"><a style=\"font-size: 16px;\" href=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2025\/11\/Image7.png\"><img loading=\"lazy\" decoding=\"async\" width=\"285\" height=\"388\" class=\"alignnone size-full wp-image-16155 img-responsive\" src=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2025\/11\/Image7.png\" alt=\"\" srcset=\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2025\/11\/Image7.png 285w, http:\/\/themacs-engineering.com\/wp-content\/uploads\/2025\/11\/Image7-220x300.png 220w\" sizes=\"(max-width: 285px) 100vw, 285px\" \/><\/a><\/h3>\r\n<h3 class=\"ai-optimize-30\"><strong>CTE measurement:<\/strong><\/h3>\r\n<p class=\"ai-optimize-31\">Measurement of expansion between 10 and 300K.<\/p>\r\n<p class=\"ai-optimize-32\">An option on the bench also allows for mechanical characterization under cryogenic conditions, including measurement of the modulus of elasticity, tensile strength, and coefficient of thermal expansion (CTE). These measurements down to 20 K provide a comprehensive understanding of material behavior for liquid hydrogen applications.<\/p>","protected":false},"excerpt":{"rendered":"Thermo-physical characterisation of materials down to 20 K for liquid hydrogen Download the brochure THEMACS Engineering markets a thermophysical property measurement bench dedicated to liquid hydrogen applications, operational down to 20 K. This system enables the precise characterization of materials and components under cryogenic conditions (thermal conductivity, thermal resistance, associated behaviors), as close as possible [&hellip;]","protected":false},"author":3,"featured_media":16566,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":""},"categories":[43],"tags":[],"class_list":["post-16205","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-actualites-en"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v25.2 (Yoast SEO v25.2) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>20 K cryogenic bench for characterising liquid hydrogen materials<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"20 K cryogenic bench for characterising liquid hydrogen materials\" \/>\n<meta property=\"og:description\" content=\"Thermo-physical characterisation of materials down to 20 K for liquid hydrogen Download the brochure THEMACS Engineering markets a thermophysical property measurement bench dedicated to liquid hydrogen applications, operational down to 20 K. This system enables the precise characterization of materials and components under cryogenic conditions (thermal conductivity, thermal resistance, associated behaviors), as close as possible [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Themacs Ing\u00e9nierie\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-12T10:32:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-12T11:49:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1634\" \/>\n\t<meta property=\"og:image:height\" content=\"1909\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"monchau\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"monchau\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/\",\"url\":\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/\",\"name\":\"20 K cryogenic bench for characterising liquid hydrogen materials\",\"isPartOf\":{\"@id\":\"http:\/\/themacs-engineering.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#primaryimage\"},\"image\":{\"@id\":\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg\",\"datePublished\":\"2026-01-12T10:32:57+00:00\",\"dateModified\":\"2026-01-12T11:49:01+00:00\",\"author\":{\"@id\":\"http:\/\/themacs-engineering.com\/en\/#\/schema\/person\/3c6a7e9c0ddbb9ea10af0e81d0963912\"},\"breadcrumb\":{\"@id\":\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#primaryimage\",\"url\":\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg\",\"contentUrl\":\"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg\",\"width\":1634,\"height\":1909,\"caption\":\"Banc de mesure\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"http:\/\/themacs-engineering.com\/en\/home\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"News\",\"item\":\"http:\/\/themacs-engineering.com\/en\/actualites-en\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"20 K cryogenic bench for characterising liquid hydrogen materials\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/themacs-engineering.com\/en\/#website\",\"url\":\"http:\/\/themacs-engineering.com\/en\/\",\"name\":\"Themacs Ing\u00e9nierie\",\"description\":\"Engineering in Ile-de-France\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/themacs-engineering.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"http:\/\/themacs-engineering.com\/en\/#\/schema\/person\/3c6a7e9c0ddbb9ea10af0e81d0963912\",\"name\":\"monchau\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"http:\/\/themacs-engineering.com\/en\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/3e22d152416e67319e11c7f41e74de64?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/3e22d152416e67319e11c7f41e74de64?s=96&d=mm&r=g\",\"caption\":\"monchau\"},\"url\":\"http:\/\/themacs-engineering.com\/en\/author\/monchau\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"20 K cryogenic bench for characterising liquid hydrogen materials","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/","og_locale":"en_GB","og_type":"article","og_title":"20 K cryogenic bench for characterising liquid hydrogen materials","og_description":"Thermo-physical characterisation of materials down to 20 K for liquid hydrogen Download the brochure THEMACS Engineering markets a thermophysical property measurement bench dedicated to liquid hydrogen applications, operational down to 20 K. This system enables the precise characterization of materials and components under cryogenic conditions (thermal conductivity, thermal resistance, associated behaviors), as close as possible [&hellip;]","og_url":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/","og_site_name":"Themacs Ing\u00e9nierie","article_published_time":"2026-01-12T10:32:57+00:00","article_modified_time":"2026-01-12T11:49:01+00:00","og_image":[{"width":1634,"height":1909,"url":"https:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg","type":"image\/jpeg"}],"author":"monchau","twitter_misc":{"Written by":"monchau","Estimated reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/","url":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/","name":"20 K cryogenic bench for characterising liquid hydrogen materials","isPartOf":{"@id":"http:\/\/themacs-engineering.com\/en\/#website"},"primaryImageOfPage":{"@id":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#primaryimage"},"image":{"@id":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#primaryimage"},"thumbnailUrl":"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg","datePublished":"2026-01-12T10:32:57+00:00","dateModified":"2026-01-12T11:49:01+00:00","author":{"@id":"http:\/\/themacs-engineering.com\/en\/#\/schema\/person\/3c6a7e9c0ddbb9ea10af0e81d0963912"},"breadcrumb":{"@id":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#primaryimage","url":"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg","contentUrl":"http:\/\/themacs-engineering.com\/wp-content\/uploads\/2026\/01\/Banc.jpg","width":1634,"height":1909,"caption":"Banc de mesure"},{"@type":"BreadcrumbList","@id":"http:\/\/themacs-engineering.com\/en\/actualites-en\/un-dispositif-de-test-de-fuite-a-20k-a-100bar-pour-lhydrogene-liquide-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"http:\/\/themacs-engineering.com\/en\/home\/"},{"@type":"ListItem","position":2,"name":"News","item":"http:\/\/themacs-engineering.com\/en\/actualites-en\/"},{"@type":"ListItem","position":3,"name":"20 K cryogenic bench for characterising liquid hydrogen materials"}]},{"@type":"WebSite","@id":"http:\/\/themacs-engineering.com\/en\/#website","url":"http:\/\/themacs-engineering.com\/en\/","name":"Themacs Ing\u00e9nierie","description":"Engineering in Ile-de-France","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/themacs-engineering.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"http:\/\/themacs-engineering.com\/en\/#\/schema\/person\/3c6a7e9c0ddbb9ea10af0e81d0963912","name":"monchau","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"http:\/\/themacs-engineering.com\/en\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/3e22d152416e67319e11c7f41e74de64?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3e22d152416e67319e11c7f41e74de64?s=96&d=mm&r=g","caption":"monchau"},"url":"http:\/\/themacs-engineering.com\/en\/author\/monchau\/"}]}},"lang":"en","translations":{"en":16205,"fr":16616,"de":16220,"es":16236,"it":16268},"_links":{"self":[{"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/posts\/16205","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/comments?post=16205"}],"version-history":[{"count":18,"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/posts\/16205\/revisions"}],"predecessor-version":[{"id":16634,"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/posts\/16205\/revisions\/16634"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/media\/16566"}],"wp:attachment":[{"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/media?parent=16205"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/categories?post=16205"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/themacs-engineering.com\/en\/wp-json\/wp\/v2\/tags?post=16205"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}